Technical Specication
Nominal Size
130 mm / 4½″
Accuracy Class
Class 1.0,
Class 0.5 optional
Ingress Protection
IP 65 (Weather tight)
Connection Size
G½ or ½ NPT or others
Scale Range
Pressure 0..1600 bar
Vacuum -1 bar..0
Compound -1..24 bar
Tube Element Shape
P≤ 100 bar in C tube
P> 100 bar in helicoil
|
Filling
Dry or liquid filled
Operating Temperature •
Ambient temperature -30°..+70℃
Medium temperature 100℃ Max.
Temperature
Additional error when pressure element
temperature deviates from reference
temperature +20℃(+68℉)
be ±0.4% / 10℃(50℉) rising or falling
Over Pressure Limit
130% of F.S. P ≤ 100 bar
115% of F.S. P > 100 bar
Dial Graduation
Black graduation on white for single range
Black and red graduation on white for dualranges
|
Design Material
Casing and Bezel Ring
Polypropylene or
Phenolic optional
Sensing Element
Stainless steel 316
Window
Safety laminated glass
Window gasket
Industrial rubber seal or PTFE
Pointer
Black aluminum, adjustable
Dial Plate Aluminum alloy
|